Dolomite
Developed on the basis of the flagship product Metabolic breathing simulator OXY ROBOT
Gallery
Test equipment "Dolomite" determines the resistance of respirators to dusting. It consists of a dust chamber and a breathing simulator with an inflatable head dummy for perfect obturation.
The necessary test conditions are created in the dust chamber, and the breathing machine simulates the external breathing of a person with the necessary parameters of the volume and frequency of pulmonary ventilation, the “exhalation” temperature of 37 0С and relative humidity of at least 95%.
As a result of the test, the time is fixed when the RPE under test has reached the resistance to air flow in the process of dusting. Then you will be able to compare the obtained results with the regulatory requirements for the RPE being tested.
Features
The software and technical capabilities of the “Dolomite” test equipment are suitable for most tests of filtering masks according to international standards, and in case of changes or new ones, you do not have to partially or completely replace the equipment - the settings are simply and flexibly changed * in the software.
This feature will allow you to conduct tests according to your research scenarios.
*within technical possibilities
Modern way of control
To control the test equipment, an application is used on a touch-screen display and the app on personal computer with a simple and convenient interface in English. It is possible to quickly and easily master the control of the "Dolomite" and involve even a laboratory intern in the work.
Read about own softwareIncreases the productivity of the testing process
Saves time for lab staff
Test equipment «Dolomite» software automatically maintains test parameters, records and stores their results,
and
saves staff time.
Lightweight design and advanced ergonomics
Weight – no more 200 kgData sheet
Technical specifications
Software features
- feedback of test results in real-time
- dust concentration control
- airflow speed control
- automatic control of test parameters, fixation and formation of a test database with results
- to export test results to your devices in PDF&EXCEL-file and print its
- to create DATABASE of relevant standards, test modes, types and models of RPE, manufactures of RPE
- self-diagnosis
- calibration
Relevant standarts
Testing respirators according to:
EN 149
EN 143
EN 13274-8
EN 405
EN 1827
EN 12941
EN 12942
EN 14387
Service
Warranty from 12 months
Training of the Customer's staff
Service support for the entire period of use
Development of equipment according to your terms of reference
If you are interesting in this test equipment, please, fill out
an application for a consultation.